DTSD341-5 Three Phase Irrigation Pump Usage Liquid Pre-paid meter

DTSD341-5 Three Phase Irrigation Pump Usage Liquid Pre-paid meter

Overview

1.1  Basic Features

1.1.1 Main parameter

ITEM                                       SPECIFICATIONS
Rated Voltage                         3×240 V /500V
Range of Voltage                   0.7Un—1.3Un
Operation Temperature        -35℃~+65℃
Rated Current                        25(100)A
Humidity                                  0 to 95% without condensation
Rated Frequency                   47.5-52.5 Hz
Starting current                      4‰Ib(class1)
Power Consumption          <2W,4VA
Life                                          ≥10 years
 

1.1.2  Real time clock

Timing Error                         25℃:±5ppm;
Clock Frequency                 1Hz
Battery Life                            10year
Continuous                           Work Time ≥5year
 

1.1.3 Power Impulse Output

Impulse output constants   200imp/kvarh.
 

1.1.4 Dimensions

Dimensions                          L×W×H = 280mm×175mm×92mm
Net weight                              About 2 kg
 
1.1.5 Applicable Standards
Standards                               Description
IEC62053-21:2003               -Operated by 2 mode such as time management & operator mode
                                                 -Using irrigation sector for pumping water
                                                 -Electricity metering equipment (a.c.) –Particular requirements –Part 21:Static meters for active energy(classes 1 and 2)
 
 
 
1.1.6 Using Field:
BADC                                    Bangladesh Agricultural Development Corporation under Ministry of Agriculture, GOB
BMDA                                    Barind Multipurpose Development Authority under Ministry of Agriculture, GOB.
BWDB                                   Bangladesh Water Development Board
 
 

 

 

 